Validation of Resting Diastolic Pressure Ratio Calculated by a Novel Algorithm and Its Correlation With Distal Coronary Artery Pressure to Aortic Pressure, Instantaneous Wave-Free Ratio, and Fractional Flow Reserve



Validation of Resting Diastolic Pressure Ratio Calculated by a Novel Algorithm and Its Correlation With Distal Coronary Artery Pressure to Aortic Pressure, Instantaneous Wave-Free Ratio, and Fractional Flow Reserve



Circulation. Cardiovascular Interventions 11(12): E006911-E006911



Instantaneous wave-free ratio (iFR) offers a reliable non-hyperemic assessment of coronary physiology but requires dedicated proprietary software with a fully automated algorithm. We hypothesized that dPR (diastolic pressure ratio), calculated with novel universal software, has a strong correlation with iFR, similar diagnostic accuracy relative to resting distal coronary artery pressure/aortic pressure and fractional flow reserve (FFR). The dPR study is an observational, retrospective, single-center cohort study including patients who underwent iFR or FFR. Dedicated software was used to calculate the dPR from Digital Imaging and Communications in Medicine (DICOM) pressure waveforms. The flat period on the pressure difference between sample (dP) to the time difference between the same sample points (dt) signal was used to detect automatically the period, where the resistance is low and constant, and to calculate the dPR, which is an average over 5 consecutive heartbeats. The software was validated by correlating iFR results with dPR. Software validation was done by comparing 78 iFR measurements in 44 patients who underwent iFR. Mean iFR and dPR were 0.91±0.10 and 0.92±0.10, respectively, with a significant linear correlation ( R=0.997; P<0.001). Diagnostic accuracy was tested in 100 patients who underwent FFR. Mean FFR, resting distal coronary artery pressure/aortic pressure, and dPR were 0.85±0.09, 0.94±0.05, and 0.93±0.07, respectively. There was a significant linear correlation between dPR and FFR ( R=0.77; P<0.001). Both distal coronary artery pressure/aortic pressure and dPR had good diagnostic accuracy in the identification of lesions with an FFR ≤0.80 (area under the curve, 0.84; 95% CI, 0.76-0.92 and 0.86; 95% CI, 0.78-0.93, respectively). dPR, calculated by a novel validated software tool, showed a strong linear correlation with iFR. dPR correlated well with FFR with a good diagnostic accuracy to identify positive FFR.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 066017789

Download citation: RISBibTeXText

PMID: 30562091

DOI: 10.1161/circinterventions.118.006911


Related references

A Comparison between the Instantaneous Wave-free Ratio and Resting Distal Coronary Artery Pressure/Aortic Pressure and the Fractional Flow Reserve: The Diagnostic Accuracy Can Be Improved by the Use of both Indices. Internal Medicine 56(7): 749-753, 2017

TCT-515 Prognostic implications of instantaneous wave-free ratio (iFR) and resting distal-to-aortic pressure ratio (Pd/Pa) compared with fractional flow reserve (FFR). A 10-year follow-up study after deferral of revascularization. Journal of the American College of Cardiology 68(18): B207-B208, 2016

Agreement of the Resting Distal to Aortic Coronary Pressure With the Instantaneous Wave-Free Ratio. Journal of the American College of Cardiology 70(17): 2105-2113, 2017

Similarity and Difference of Resting Distal to Aortic Coronary Pressure and Instantaneous Wave-Free Ratio. Journal of the American College of Cardiology 70(17): 2114-2123, 2017

Study of diagnostic efficiencies of pressure indices (rest pd/pa, instantaneous wave free ratio, contrast fractional flow reserve) against fractional flow reserve 0.80 in intermediate coronary lesions. Indian Heart Journal 70: S71-S72, 2018

Discordance Between Resting and Hyperemic Indices of Coronary Stenosis Severity: The VERIFY 2 Study (A Comparative Study of Resting Coronary Pressure Gradient, Instantaneous Wave-Free Ratio and Fractional Flow Reserve in an Unselected Population Referred for Invasive Angiography). Circulation. Cardiovascular Interventions 9(11), 2017

Reconciling poststenotic pressure with hyperemic flow: comparing coronary flow reserve, instantaneous wave-free ratio, and fractional flow reserve. Circulation. Cardiovascular Interventions 7(4): 432-434, 2015

Baseline instantaneous wave-free ratio as a pressure-only estimation of underlying coronary flow reserve: results of the JUSTIFY-CFR Study (Joined Coronary Pressure and Flow Analysis to Determine Diagnostic Characteristics of Basal and Hyperemic Indices of Functional Lesion Severity-Coronary Flow Reserve). Circulation. Cardiovascular Interventions 7(4): 492-502, 2015

Physiologic and Clinical Assessment of Resting Physiologic Indices: Resting Full-Cycle Ratio, Diastolic Pressure-Ratio, and Instantaneous Wave-Free Ratio. Circulation 2018, 2018

Quantification of the Effect of Pressure Wire Drift on the Diagnostic Performance of Fractional Flow Reserve, Instantaneous Wave-Free Ratio, and Whole-Cycle Pd/Pa. Circulation. Cardiovascular Interventions 9(4): E002988, 2016

Physiological Pattern of Disease Assessed by Pressure-Wire Pullback Has an Influence on Fractional Flow Reserve/Instantaneous Wave-Free Ratio Discordance. Circulation. Cardiovascular Interventions 12(5): E007494, 2019

Combining Baseline Distal-to-Aortic Pressure Ratio and Fractional Flow Reserve in the Assessment of Coronary Stenosis Severity. Jacc. Cardiovascular Interventions 8(13): 1681-1691, 2016

Relationship between coronary diastolic pressure indexes during the wave-free period and a novel pressure-derived index: Diastolic pressure ratio at the optimal point. Catheterization and Cardiovascular Interventions 2018, 2018

Assessment of left anterior descending artery stenosis of intermediate severity by fractional flow reserve, instantaneous wave-free ratio, and non-invasive coronary flow reserve. International Journal of Cardiovascular Imaging 33(7): 999-1007, 2016

Assessment of left anterior descending artery stenosis of intermediate severity by fractional flow reserve, instantaneous wave-free ratio and non-invasive coronary flow reserve. Annales de Cardiologie et d'Angéiologie 65(5): 380-381, 2016