Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality



Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality



Investigative Radiology 54(5): 265-272



The aim of this study was to investigate the effects of a modern automatic tube current modulation (ATCM) and automatic tube voltage selection (ATVS) system on radiation dose and image quality in pediatric head, and torso computed tomography (CT) examinations for various clinical indications. Four physical anthropomorphic phantoms that represent the average individual as neonate, 1-year-old, 5-year-old, and 10-year-old child were used. Standard head, thorax, and abdomen/pelvis acquisitions were performed with (1) fixed tube current, (2) ATCM, and (3) ATVS. Acquisitions were performed at various radiation dose levels to generate images at different levels of quality. Reference volume CT dose index (CTDIvol), reference image noise, and reference contrast-to-noise ratios were determined. The potential dose reductions with ATCM and ATVS were assessed. The percent reduction of CTDIvol with ATCM ranged from 8% to 24% for head, 16% to 39% for thorax, and 25% to 41% for abdomen/pelvis. The percent reduction of CTDIvol with ATVS varied on the clinical indication. In CT angiography, ATVS resulted to the highest dose reduction, which was up to 70% for head, 77% for thorax, and 34% for abdomen/pelvis. In noncontrast examinations, ATVS increased dose by up to 21% for head, whereas reduced dose by up to 34% for thorax and 48% for abdomen/pelvis. In pediatric CT, the use of ATCM significantly reduces radiation dose and maintains image noise. The additional use of ATVS reduces further the radiation dose for thorax and abdomen/pelvis, and maintains contrast-to-noise ratio for the specified clinical diagnostic task.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 066017953

Download citation: RISBibTeXText

PMID: 30562273

DOI: 10.1097/rli.0000000000000537


Related references

Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study. Academic Radiology 16(8): 997-1002, 2009

The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study. Journal of X-Ray Science and Technology 21(4): 453-464, 2013

New organ-based tube current modulation method to reduce the radiation dose during computed tomography of the head: evaluation of image quality and radiation dose to the eyes in the phantom study. La Radiologia Medica 122(8): 601-608, 2017

Potential for radiation dose savings in abdominal and chest CT using automatic tube voltage selection in combination with automatic tube current modulation. Ajr. American Journal of Roentgenology 203(2): 292-299, 2014

Iterative reconstruction and individualized automatic tube current selection reduce radiation dose while maintaining image quality in 320-multidetector computed tomography coronary angiography. Clinical Radiology 68(11): E570, 2013

Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: a phantom study. Clinical Radiology 68(2): E79, 2013

Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol. Journal of Cardiovascular Computed Tomography 6(3): 184-190, 2012

Assessment of image quality on effects of varying tube voltage and automatic tube current modulation with hybrid and pure iterative reconstruction techniques in abdominal/pelvic CT: a phantom study. Investigative Radiology 48(3): 167-174, 2013

Radiation dose and image quality with abdominal computed tomography with automated dose-optimized tube voltage selection. Journal of International Medical Research 42(4): 1011-1017, 2014

Effects of automatic tube potential selection on radiation dose index, image quality, and lesion detectability in pediatric abdominopelvic CT and CTA: a phantom study. European Radiology 26(1): 157-166, 2016

Cardiac computed tomography angiography with automatic tube potential selection: effects on radiation dose and image quality. Journal of Thoracic Imaging 28(1): 40-48, 2013

Comparison of image quality and radiation dose between fixed tube current and combined automatic tube current modulation in craniocervical CT angiography. Ajnr. American Journal of Neuroradiology 30(9): 1754-1759, 2009

Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis. Acta Radiologica 52(10): 1101-1106, 2011

Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique. Medical Physics 42(11): 6572-6578, 2015

Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique. International Journal of Cardiovascular Imaging 30(Suppl. 2): 89-94, 2014