Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation



Comparative Study of Volume Computed Tomography Dose Index and Size-Specific Dose Estimate Head in Computed Tomography Examination for Adult Patients Based on the Mode of Automatic Tube Current Modulation



Medical Science Monitor 25: 71-76



BACKGROUND The aim of this study was to compare the metrics of volume computed tomography index (CTDIvol) and size-specific dose estimate (SSDE), and quantity the differences in head CT examinations of adult patients. MATERIAL AND METHODS A total of 157 patients underwent head CT examination were enrolled in this retrospective study. Pearson correlation analysis and linear regression correlation analysis were performed to observe the correlation between the dose metrics of CTDIvol and SSDEaver versus tube current product (mAs) and water equivalent diameter (WED). Correlated factors of CTDIvol and SSDEaver were analyzed by multivariate linear stepwise regression analysis. RESULTS A sum of 4239 data settings were measured: slices with WED >16 cm was 71.05%, and the slices with f <1 was 72.64%. The average value of the absolute difference between WED and the diameter of AAPM head phantom was 2.24±1.42 cm. Statistically significant difference was found between the values of CTDIvol and SSDEaver (P=0.000). The dispersion degree of the CTDIvol values was greater than that of SSDEaver. Strong positive correlation was shown between CTDIvol and mAs (P=0.000), as well as CTDIvol and WED (P=0.000). Strong positive correlation was shown between SSDEaver and mAs (P=0.000), and moderate correlation for SSDEaver and WED (P=0.000). Both the metrics of mAs and WED were included in the multivariate linear stepwise regression equation to observe the effect of related factors on the value of SSDEaver. CONCLUSIONS SSDEaver with better representative can reproduce the radiation dosage of the specific adult patients in head CT examination.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 066055507

Download citation: RISBibTeXText

PMID: 30604739


Related references

Signal-to-noise ratio and dose to the lens of the eye for computed tomography examination of the brain using an automatic tube current modulation system. Emergency Radiology 24(3): 233-239, 2017

Use of automatic tube current modulation with a standardized noise index in young children undergoing chest computed tomography scans with 64-slice multidetector computed tomography. Acta Radiologica 50(10): 1175-1181, 2009

Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI(vol)). European Radiology 24(8): 1959-1963, 2014

New organ-based tube current modulation method to reduce the radiation dose during computed tomography of the head: evaluation of image quality and radiation dose to the eyes in the phantom study. La Radiologia Medica 122(8): 601-608, 2017

Dose study of electrocardiogram automatic tube current modulation technology in prospective coronary computed tomography angiography scans of overweight patients. Experimental and Therapeutic Medicine 9(6): 2384-2388, 2015

Size-based protocol optimization using automatic tube current modulation and automatic kV selection in computed tomography. Journal of Applied Clinical Medical Physics 17(1): 328-341, 2016

Craniocervical computed tomography angiography with adaptive iterative dose reduction 3D algorithm and automatic tube current modulation in patients with different body mass indexes. Medicine 97(36): E11841, 2018

Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality. Investigative Radiology 54(5): 265-272, 2019

Influence of Localizer and Scan Direction on the Dose-Reducing Effect of Automatic Tube Current Modulation in Computed Tomography. Radiation Protection Dosimetry 169(1-4): 136-142, 2016

Evaluation of the individual tube current setting in electrocardiogram-gated cardiac computed tomography estimated from plain chest computed tomography using computed tomography automatic exposure control. Nihon Hoshasen Gijutsu Gakkai Zasshi 69(5): 508-513, 2013

A Study to Determine Whether the Volume-Weighted Computed Tomography Dose Index Gives Reasonable Estimates of Organ Doses for Thai Patients Undergoing Abdomen and Pelvis Computed Tomography Examinations. Journal of Medical Physics 42(4): 266-272, 2018

The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study. Journal of X-Ray Science and Technology 21(4): 453-464, 2013

Reduction of patient radiation dose with a new organ based dose modulation technique for thoraco-abdominopelvic computed tomography (CT) (Liver dose right index). Diagnostic and Interventional Imaging 99(7-8): 483-492, 2018

Evaluation of dose output according to the objects using organ-based tube-current modulation in thoracic computed tomography. Nihon Hoshasen Gijutsu Gakkai Zasshi 70(11): 1297-1303, 2014

Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions. European Radiology 10(2): 391-394, 2000