Optimal Hemodynamics During Left Ventricular Assist Device Support Are Associated With Reduced Readmission Rates



Optimal Hemodynamics During Left Ventricular Assist Device Support Are Associated With Reduced Readmission Rates



Circulation. Heart Failure 12(2): E005094



Left ventricular assist device (LVAD) therapy improves the hemodynamics of advanced heart failure patients. However, it is unknown whether hemodynamic optimization improves clinical outcomes. The aim of this study was to investigate whether hemodynamic optimization reduces hospital readmission rate in LVAD patients. LVAD patients undergoing an invasive hemodynamic ramp test were prospectively enrolled and followed for 1 year. LVAD speed was optimized using a ramp test, targeting the following goals: central venous pressure <12 mm Hg, pulmonary capillary wedge pressure <18 mm Hg, and cardiac index >2.2 L/(min·m2). The frequency and cause of hospital readmissions were compared between patients who achieved (optimized group) or did not achieve (nonoptimized group) these goals. Eighty-eight outpatients (median 61 years old, 53 male) underwent ramp testing 236 days after LVAD implantation, and 54 (61%) had optimized hemodynamics after LVAD speed adjustment. One-year survival after the ramp study was comparable in both groups (89% versus 88%). The total hospital readmission rate was lower in the optimized group compared with the nonoptimized group (1.15 versus 2.86 events/y, P<0.001). This result was predominantly because of a reduction in the heart failure readmission rate in the optimized group (0.08 versus 0.71 events/y, P=0.016). LVAD patients, in whom hemodynamics were optimized, had a significantly lower rate of hospital readmissions, primarily because of fewer heart failure admissions. These findings highlight the importance of achieving hemodynamic optimization in LVAD patients.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 066446405

Download citation: RISBibTeXText

PMID: 30704291

DOI: 10.1161/circheartfailure.118.005094


Related references

Optimal haemodynamics during left ventricular assist device support are associated with reduced haemocompatibility-related adverse events. European Journal of Heart Failure 2018, 2018

Post-cardiac transplant survival after support with a continuous-flow left ventricular assist device: impact of duration of left ventricular assist device support and other variables. Journal of Thoracic and Cardiovascular Surgery 140(1): 174-181, 2010

Postcardiac transplant survival after support with a continuous-flow left ventricular assist device: Impact of duration of left ventricular assist device support and other variables. Yearbook of Cardiology 2011: 171-172, 2011

Performance Improvement to Decrease Readmission Rates for Patients With a Left Ventricular Assist Device. Progress in Transplantation 28(2): 184-188, 2018

Hospital Readmission during Left Ventricular Assist Device Support: Causes, Temporal Trends, and Terminal Readmissions. Journal of Heart and Lung Transplantation 35(4): S26-S27, 2016

Fontan-Like Hemodynamics Complicated With Ventricular Fibrillation During Left Ventricular Assist Device Support. International Heart Journal 57(4): 515-518, 2017

Liberal Right Ventricular Assist Device Extracorporeal Membrane Oxygenation Support for Right Ventricular Failure after Implantable Left Ventricular Assist Device Placement. Asaio Journal 64(6): 741-747, 2017

Temporary extracorporeal left ventricular assist device support for implantable left ventricular assist device replacement cases. Journal of Thoracic and Cardiovascular Surgery 147(4): E46-E48, 2014

Reducing 30-Day Hospital Readmission Rate in Left Ventricular Assist Device Patients with a Structured Readmission Improvement Plan. Journal of Heart and Lung Transplantation 36(4): S197-S198, 2017

Right ventricular assist device with membrane oxygenator support for right ventricular failure following implantable left ventricular assist device placement. European Journal of Cardio-Thoracic Surgery 49(1): 73-77, 2016

Readmission due to driveline infection can be predicted by new score by using serum albumin and body mass index during long-term left ventricular assist device support. Journal of Artificial Organs 18(2): 120-127, 2016

Effects of exercise during long-term support with a left ventricular assist device. Results of the experience with left ventricular assist device with exercise (EVADE) pilot trial. Circulation 95(10): 2401-2406, 1997

Outcome of unplanned right ventricular assist device support for severe right heart failure after implantable left ventricular assist device insertion. Journal of Heart and Lung Transplantation 33(2): 141-148, 2014

Effects of continuous flow left ventricular assist device support on skin tissue microcirculation and aortic hemodynamics. Asaio Journal 49(1): 103-107, 2003

Transesophageal echocardiography diagnosis of extracardiac left ventricular assist device inflow cannula obstruction in a patient with thoratec intracorporeal ventricular assist device biventricular support. Journal of the American Society of Echocardiography 21(6): 777.E5-6, 2007