+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Hemodynamic analysis of a novel stent graft design with slit perforations in thoracic aortic aneurysm



Hemodynamic analysis of a novel stent graft design with slit perforations in thoracic aortic aneurysm



Journal of Biomechanics 2019



Thoracic endovascular aortic repair (TEVAR) has been introduced as a less invasive approach to the treatment of thoracic aortic aneurysm (TAA). However, the effectiveness of TEVAR in the treatment of TAA is often limited due to the complex anatomy of aortic arch. Flow preservation at the three supra-aortic branches further increases the overall technical difficulty. This study proposes a novel stent graft design with slit perforations that can positively alter the hemodynamics at the aortic arch while maintaining blood flow to supra-aortic branches. We carried out a computational fluid dynamic (CFD) analysis to evaluate flow characteristics near stented aortic arch in simplified TAA models, followed by in-vitro experiments using particle image velocimetry (PIV) in a mock circulatory loop. The hemodynamics result was studied in terms of time-averaged wall shear stress (TAWSS), oscillating shear index (OSI), and endothelial cell action potential (ECAP). The results showed that the stent graft with slit perforations can reduce the disturbed flow region considerably. Furthermore, the effect of the slits on flow preservation to the supra-aortic branches was simulated and compared with experimental results. The effectiveness of the stent graft with slit perforations in preserving flow to the branches was demonstrated by both simulated and experimental results. Low TAWSS and elevated ECAP were observed in the aortic arch aneurysm after the placement of the stent graft with slits, implying the potential of thrombus formation in the aneurysm. On the other hand, the effects of the stent grafts with full-slit design and half-slit design on the shear stress did not differ significantly. The present analysis indicated that not only could the stent graft with slit perforations shield the aneurysm from rupture, but also it resulted in a favorable environment for thrombus that can contribute to the shrinkage of the aneurysm.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 066446824

Download citation: RISBibTeXText

PMID: 30704763

DOI: 10.1016/j.jbiomech.2019.01.019


Related references

Endovascular repair of a ruptured descending thoracic aortic aneurysm in a patient with an ascending aortic aneurysm: hybrid open arch reconstruction with simultaneous thoracic stent-graft deployment within elephant trunk. Annals of Vascular Surgery 22(2): 168-172, 2008

Preliminary report on prediction of spinal cord ischemia in endovascular stent graft repair of thoracic aortic aneurysm by retrievable stent graft. Journal of Thoracic and Cardiovascular Surgery 115(4): 811-818, 1998

The modified chimney technique with a thoracic aortic stent graft to preserve the blood flow of the left common carotid artery for treating descending thoracic aortic aneurysm and dissection. Korean Circulation Journal 42(5): 360-365, 2012

Multi-institutional pivotal trial of the Zenith TX2 thoracic aortic stent-graft for treatment of descending thoracic aortic aneurysms: clinical study design. Perspectives in Vascular Surgery and Endovascular Therapy 17(3): 255-264, 2005

Thoracic CT findings following endovascular stent-graft treatment for thoracic aortic aneurysm. Journal of Endovascular Therapy 14(3): 333-341, 2007

Descending thoracic aortic aneurysm: thoracic CT findings after endovascular stent-graft placement. Radiology 212(1): 169-174, 1999

Thoracic stent graft with distal fenestration for the superior mesenteric artery for treatment of thoracic aortic aneurysm. Annals of Vascular Diseases 7(2): 152-155, 2014

Endovascular stent-graft repair for thoracic aortic aneurysm associated with right-sided aortic arch. Journal of Thoracic and Cardiovascular Surgery 122(1): 185-186, 2001

Dislocation of a stent-graft into the aortic arch during endovascular repair of a descending thoracic aortic aneurysm. Annals of Thoracic Surgery 81(4): 1502-1505, 2006

Interventional therapy of aortic isthmus stenosis with concomitant thoracic aortic aneurysm with a stent graft. Zeitschrift für Kardiologie 89(10): 962-964, 2000

Treatment of a mycotic descending thoracic aortic aneurysm using endovascular stent-graft placement and rifampin infusion with postoperative aspiration of the aneurysm sac. Vascular and Endovascular Surgery 45(8): 765-768, 2012

False aneurysm formation at proximal and distal ends of a stent graft: a rare complication in the repair of endovascular thoracic aortic aneurysm. International Angiology 25(2): 228-230, 2006

Elective Matsui-Kitamura stent graft repair for descending thoracic aortic aneurysm and chronic type-B aortic dissection. Thoracic and Cardiovascular Surgeon 58(5): 265-270, 2010

Distal embolus protection with an intra-aortic filter during stent-graft repair of a severely atherosclerotic thoracic aortic aneurysm. Journal of Endovascular Therapy 12(6): 642-646, 2005

A Comparative Analysis of the Influence of Stent Graft Design on Long-Term Outcomes After Endovascular Abdominal Aortic Aneurysm Repair. Journal of Vascular Surgery 62(2): 530-531, 2015