Effect of CT Localizer Radiographs on Radiation Dose Associated With Automatic Tube Current Modulation: A Multivendor Study



Effect of CT Localizer Radiographs on Radiation Dose Associated With Automatic Tube Current Modulation: A Multivendor Study



Current Problems in Diagnostic Radiology 49(1): 34-41



To assess the influence of the CT localizer radiograph on the automatic tube current modulation system of 7 CT scanners produced by 4 different CT manufacturers. The influence of the localizer orientation, table height, tube current and tube potential values on the radiation dose of the related CT scan were evaluated. Images were acquired by using an anthropomorphic phantom positioned in the CT gantry isocenter as well as from -6 cm to +6 cm vertically to the isocenter. Vertical movement of the CT table height affected the radiation dose in all scanners using anterior-posterior or a posterior-anterior localizer orientation albeit differently, depending on the manufacturer; only in 1/7 scanner no influence was observed. The latero-lateral localizer orientation proved to be more effective in limiting the influence of the vertical miscentering in all scanners. Changing localizer's tube voltage influenced the scan radiation dose in scanners produced by two manufacturers, while no significant effect was observed in scanners produced by the other two manufacturers. No significant dose variation was observed in 6/7 scanners when changing the localizer's tube current. Localizer radiograph shows a significant influence on the radiation exposure but with different outcomes depending on the manufacturer of the CT scanner. Radiologists and radiographers should have a thorough understanding of these differences to assure patients the best examination in terms of radiation dose and image quality.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 066446829

Download citation: RISBibTeXText

PMID: 30704769

DOI: 10.1067/j.cpradiol.2018.12.010


Related references

Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation. Radiology 282(3): 842-849, 2017

Influence of Localizer and Scan Direction on the Dose-Reducing Effect of Automatic Tube Current Modulation in Computed Tomography. Radiation Protection Dosimetry 169(1-4): 136-142, 2016

Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study. Academic Radiology 16(8): 997, 2009

Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: phantom study. Ajr. American Journal of Roentgenology 190(2): W100-W105, 2008

Potential for radiation dose savings in abdominal and chest CT using automatic tube voltage selection in combination with automatic tube current modulation. Ajr. American Journal of Roentgenology 203(2): 292-299, 2014

Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality. Investigative Radiology 54(5): 265-272, 2019

Comparison of image quality and radiation dose between fixed tube current and combined automatic tube current modulation in craniocervical CT angiography. Ajnr. American Journal of Neuroradiology 30(9): 1754-1759, 2009

Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis. Acta Radiologica 52(10): 1101-1106, 2011

The application of automatic tube current modulation (ATCM) on image quality and radiation dose at abdominal computed tomography (CT): A phantom study. Journal of X-Ray Science and Technology 21(4): 453-464, 2013

Do metallic endoprostheses increase radiation dose associated with automatic tube-current modulation in abdominal-pelvic MDCT? A phantom and patient study. Ajr. American Journal of Roentgenology 184(2): 491-496, 2005

Whole-body CT with high heat-capacity X-ray tube and automated tube current modulation--effect of tube current limitation on contrast enhancement, image quality and radiation dose. European Journal of Radiology 84(5): 877-883, 2015

Effect of localizer radiograph on radiation dose associated with automatic exposure control: human cadaver and patient study. Journal of Computer Assisted Tomography 38(2): 293-298, 2014

Performance of adaptive iterative dose reduction 3D integrated with automatic tube current modulation in radiation dose and image noise reduction compared with filtered-back projection for 80-kVp abdominal CT: Anthropomorphic phantom and patient study. European Journal of Radiology 85(9): 1666-1672, 2016

Image Quality and Radiation Dose of CT Coronary Angiography with Automatic Tube Current Modulation and Strong Adaptive Iterative Dose Reduction Three-Dimensional (AIDR3D). Plos one 10(11): E0142185, 2015