+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Covariance matrix based fall detection from multiple wearable sensors



Covariance matrix based fall detection from multiple wearable sensors



Journal of Biomedical Informatics 94: 103189



Falls are among the critical accidents experienced by elderly people and patients carrying some diseases. Subsequently, the detection and prevention of falls have become a hot research and industrial topic. This is due to the fact that falls are behind numerous irreversible injuries, or even death, and are weighting on the budgets of the health services. Automatic fall detection is one of the proposed solutions which aim at monitoring people who are likely to fall. Such solutions mitigate the fall impact by taking a quick action, e.g. in case of a fall occurrence, an alert is sent to the hospital. In this paper, we propose a new fall detection system relying on different signals acquired with multiple wearable sensors. Our system makes use of the covariance of the raw signals and the nearest neighbor classifier. Besides feature extraction, we also employ the covariance matrix as a straightforward mean for fusing signals from multiple sensors, to enhance the classification performance. Evaluation on two publicly available fall datasets, namely CogentLabs and DLR, demonstrates that the proposed approach is efficient when exploiting a single sensor as well as when fusing data from multiple sensors. Geodesic metrics are found to provide a higher fall detection accuracy than the Euclidean metric. The best obtained classification accuracies are 92.51% and 98.31% for CogentLabs and DLR datasets, respectively.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 066730940

Download citation: RISBibTeXText

PMID: 31029654

DOI: 10.1016/j.jbi.2019.103189


Related references

Assessing fall risk using wearable sensors: a practical discussion. A review of the practicalities and challenges associated with the use of wearable sensors for quantification of fall risk in older people. Zeitschrift für Gerontologie und Geriatrie 45(8): 694-706, 2012

Evaluation of Feature Extraction and Recognition for Activity Monitoring and Fall Detection Based on Wearable sEMG Sensors. Sensors 17(6):, 2017

Survey on fall detection and fall prevention using wearable and external sensors. Sensors 14(10): 19806-19842, 2014

Wearable sensors for reliable fall detection. Conference Proceedings 4: 3551-3554, 2005

Analysis of a Smartphone-Based Architecture with Multiple Mobility Sensors for Fall Detection. Plos one 11(12): E0168069, 2016

Freezing of gait and fall detection in Parkinson's disease using wearable sensors: a systematic review. Journal of Neurology 264(8): 1642-1654, 2017

Analysis of a Smartphone-Based Architecture with Multiple Mobility Sensors for Fall Detection with Supervised Learning. Sensors 18(4):, 2018

Prospective Fall-Risk Prediction Models for Older Adults Based on Wearable Sensors. IEEE Transactions on Neural Systems and Rehabilitation Engineering 25(10): 1812-1820, 2017

A level-crossing based QRS-detection algorithm for wearable ECG sensors. IEEE Journal of Biomedical and Health Informatics 18(1): 183-192, 2014

Development of a wearable-sensor-based fall detection system. International Journal of Telemedicine and Applications 2015: 576364, 2015

Toward wearable sensors: optical sensor for detection of ammonium nitrate-based explosives, ANFO and ANNM. Chemical Communications 53(37): 5196-5199, 2017

Signal estimation based on covariance information from observations featuring correlated uncertainty and coming from multiple sensors. Signal Processing 88(12): 2998-3006, 2008

Clinical assessment of gait in individuals with multiple sclerosis using wearable inertial sensors: Comparison with patient-based measure. Multiple Sclerosis and Related Disorders 10: 187-191, 2016

Multi-Target Angle Tracking Algorithm for Bistatic Multiple-Input Multiple-Output (MIMO) Radar Based on the Elements of the Covariance Matrix. Sensors 18(3):, 2018

Tonic-clonic seizure detection using accelerometry-based wearable sensors: A prospective, video-EEG controlled study. Seizure 65: 48-54, 2019